If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADE SIMPLE SET READER AND KEYFOBS. We hope that this ADE SIMPLE SET READER AND KEYFOBS user guide will be useful to you.
Manual abstract: user guide ADE SIMPLE SET READER AND KEYFOBSINSTALLATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Each keyfob is unique and can only be used if it is recongised by the reader, this provides total security. These instructions cover information on how to mount and wire the reader, how to engineer the panel and learn up to eight keyfobs to a reader and how to fully set and unset the system using a keyfob. The products covered in these instructions are:
58. 5mm
18. 5mm
Maximum of up to 4 Remote Keypad / Simple Set Reader / OPTI-CAM Lighting Controller combination allowed
TAMP
Where there is only one keypad and it is part of the panel then connect the TAMP back to the panel Cable distance 100m maximum
J5
ÿ
Reader SS/01 & SS/01/UB
Keyfob SS/F & SS/F/UB Standards Power Minimum range keyfobs Dimensions Weight Temperature Colour Mounting Indications
How to connect the Simple Set Reader to a G3 intruder panel with Software versions 1. 2 (26/11/01), 1. 1 (12/09/01), 1. 0 (08/06/01)
Cable distance 100m maximum
Simple Set Reader Board
RTT&E Directive: EN 300 330 and EN 301-489; BS EN 50130-4
-
13. 8V dc from panel +/- 5% maximum 75mA 20mm from centre of depression 8 maximum per reader
ÿ
ÿ ÿ ÿ ÿ
RELAY
SS/01- Branded Simple Set Reader with 2 pre-learnt keyfobs and a link SS/01/UB- Unbranded Simple Set Reader with 2 pre-learnt Keyfobs and a link SS/F - Branded keyfob SS/F/UB - Unbranded keyfob
OPTI-CAM Lighting Controller Board
COMMS SOUND LD R
GND 12V
Keypad
TAMP
Board
COMMS SOUND
TAMP
SOUND COMMS 13V 0V
Panel Board
RKP FUSE
4g
114g 0 to +55ºC
ÿ ÿ
0V
13V
58. 5 x 18. 5mm
118 x 84 x 22mm
1A
F2 SOUND COMMS +13V 0V
Dark Grey Polycarb. [. . . ] Keyfobs must be learnt by each reader installed in a system
Power Day Learn Error TA PA
How to set the system
When you leave your premises you will need to set (or turn on) the intruder alarm system. Before setting the system you should ensure that the premises have been completely vacated and that all doors and windows are closed. Ensure that pets do not have access to the protected areas as they can cause a false alarm.
Power Day Learn Error TA PA
Reader PCB
Ensure the reader is connected to the intruder system and the JUMPER link is fitted on the reader PCB. Power up the intruder system and enter the User code at the system keypad to unset the system. You will hear five rapid beeps to acknowledge the reader is in the Learn mode. The learn mode will NOT timeout until the first keyfob is learnt.
Ensure the reader is in the day mode with the Day light lit. You should have one learnt keyfob and the new keyfobs available.
1 2 3
By entering the learn mode in this manner you will erase all recognition of previously learnt keyfobs at the reader, except for the one used to enter the learn mode.
7 8
ZONE
4 5 6
ZONE
1 2 3 4 5 6 7 8
POWER UP THE SYSTEM
x 5 rapid beeps
The Day indicator should be lit at the reader. Offer a keyfob to the reader and withdraw it as soon as you hear the keyfob recognition beep tone from the local sounder.
7 8
JUMPER
link removed
Reader
Power Day Learn Error TA PA
Power Day Learn Error TA PA
Hold for 10 seconds
ZONE
1 2 3 4 5 6 7 8
When an unrecognised keyfob is offered to the reader it will cause the Error light to be lit and continuous sound is emitted from the local sounder. Hold the recognised `learnt' keyfob such that it touches the centre depression on the Reader and keep it there without movement for 10 seconds. You will hear a keyfob recognition beep and 10 seconds later five rapid beeps from the local sounder. The Learn light will give a flashing indication and the ZONE lights change from flashing to steady On indication to show recognised or learnt keyfob. The reader is now ready to learn the new keyfobs signalled by the next flashing ZONE indicator. In the learn mode when an already learnt keyfob is offered to the reader, an Error indication will be given. The learn mode will timeout after 10 seconds if no actions is taken to learn new keyfob Offer the new keyfob slightly touch it on the centre depression of the reader. A learnt indication is given of the new keyfob when the flashing ZONE indicator changes to steady On indication and there is a recognition beep given by the local sounder. Repeat to learn the new keyfob.
Reader
Power Day Learn Error TA PA
Hold for 20 seconds
ZONE
1 2 3 4 5 6 7 8
Ensure the reader is in the day mode with the Day light lit. You must have one learnt keyfob and up to 7 further keyfobs to be learnt. When an unrecognised keyfob is offered to the reader it will cause the Error light to be lit and continuous sound to be emitted from the local sounder. [. . . ] You now have up to 10 seconds to start learning the another keyfob.
keyfob recognised beep
Power Day Learn Error TA PA
ZONE
1 2 3 4 5 6 7 8
Reader
Offer keyfob to the Reader and withdraw
Power Day Learn Error TA PA
The system will stop the entry beep tone and light the green Day indicator.
1 2 3
ZONE
4 5 6 7 8
ZONE
1 2 3 4 5 6 7 8
ZONE
1 2 3 4 5 6 7 8
ZONE
12 3 4 5 6 7 8
If any Zone, Tamper or Attack indicator lights up then an alarm has occurred, and an intrusion may have taken place. Seek assistance before investigating further as intruders may still be on the premises. If you do not withdraw keyfob after it is recognised by the reader, you run the risk of entering the learn mode.
x 2 beeps
Power Day Learn Error TA PA
Repeat
to learn the next keyfob.
ZONE
1 2 3 4 5 6 7 8
Keyfob recognition beep
Power Day Learn Error TA PA
Once all the keyfobs are recognised `learnt' by the Reader wait for just over 10 seconds and the reader will exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
x 2 beeps
Power Day Learn Error TA PA
x 2 beeps
Power Day Learn Error TA PA
Repeat
to learn the next keyfob.
ZONE
1
ZONE
1 2 3 4 5 6 7 8
2
3
4
5
6
7
8
Once all the keyfobs are recognised `learnt' by the reader wait for just over 10 seconds for the reader to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
ZONE
1 2 3 4 5 6 7 8
Once all the keyfobs are recognised `learnt' by the reader wait for just over 10 seconds for the reader to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
Fault finding
Indication given. . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ADE SIMPLE SET READER AND KEYFOBS