User manual AXIS BTA 2100D
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AXIS BTA 2100D. We hope that this AXIS BTA 2100D user guide will be useful to you.
Manual abstract: user guide AXIS BTA 2100D
Detailed instructions for use are in the User's Guide.
[. . . ] BTA2100(D)
BTA210(D)
USER MANUAL
BTA Series
File: ER-BTA-144-05-10 btA0009 GB
2
Contents:
USER MANUAL
__________________________________________________________________________________________________________________
1. General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. Completeness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Safety rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4. [. . . ] Percent calculation functions (PErCEnt)
100%
The function allows displaying weighing result in percent. Measurement is performed in two phases: -first phase weighing reference mass (mass referenced to 100%), -second phase weighing any sample mass as a percent of reference mass measured in first phase. Weighing result is displayed in various formats, depending on reference mass value. For reference mass values between 0÷3, 5% of scale capacity, format of weighing result is 100. 0, for values between 3, 5÷35% it is 100. 00 and above 35% - 100. 000. The function has the following options: - PEr oFF switch the function off, - PEr on set current indication as 100%, show indications in %, - out exit without changes. PEr Err message informs that reference mass is less than 0, 5Min or was not defined. When the scale shows weighing result in percent, T key works as usual.
0. 00 g
19. 07 g
MENU
PErCEnt
T
PEr oFF
PEr on 50%
T
100. 00%
50. 00%
USER MANUAL
25
__________________________________________________________________________________________________________________
15. 6. Function for summing recipe ingredients (rECIPE)
0. 00 g rECIPE rEC oFF rEC on
T
MENU
T
A
The function allows for separate weighing of several ingredients in one container with the possibility of reading current sum of all weighed ingredients. The function includes the following options: -rEC oFF leave the function with the possibility of read sum mass, -rEC on start recipe weighing, -rEC Con continue previous recipe, -out exit without changes.
o 10. 01g
T
B
o
0. 00g
When proceeding with recipe, successive ingredients (A, B, C, etc. ) are weighed each time starting from zero indication, which is obtained after scale taring.
T
o 10. 02g
C
o
0. 00g
MENU
If several ingredients are weighed, their sum mass can be read (despite several taring). For this purpose use rEC oFF option.
o 10. 03g
rECIPE A+ B+ C rEC oFF 30. 06g
T
T
Comments: o indicator on the left side of scale display shows rECIPE function is active. SUM indicator shown when rEC oFF option is used, disappears after using T key.
26
USER MANUAL
__________________________________________________________________________________________________________________
15. 7. Function for calibration with external weight (CALIbr)
Calibration with external weight should be performed if scale accuracy is not satisfactory. Calibration weight stated in technical data table for the scale (or of better accuracy) should be used then. Operations sequence: Press MENU key to display user functions, shown one by one in loop. The following options will be displayed: -CAL on calibration with external recommanded value weight (see technical data). -CAL StP calibration with external weight, confirmation of next steps - MENU key, -CAL Pt calibration with external weight other value, out leave without changes Press T key when CAL on option appears. Wait for writing zero to the scale.
0. 00g CALIbr CAL oFF
MENU
T
. . .
CAL on - CAL -
T
0. 00g m LOAD m 0. 00g
When LOAD message appears put calibration weight on the pan.
Wait until internal calibration is zero indication is finished displayed. Attention:
CAL StP option generates commu-nications Press Menu.
USER MANUAL
27
__________________________________________________________________________________________________________________
15. 8. Label choosing function (LAbEL)
This function is used in scale with ELTRON (Port-1) data protocol. This protocol enables label printout with actual scale indication and chosen data from PrInt special function (variable data), for example date and time. Other data, for example company address, product name, barcode can appear on label as a constant text. Label patterns with number (4 digit) used by user should be saved in scale memory according to printer manual. [. . . ] If comparison result is: - smaller than lower threshold the balance displays MIN, - between threshold values - the balance displays OK with the sound signal when exceeding the threshold, - greater than upper threshold - the balance displays MAX with the sound signal when exceeding the threshold,
If the balance is equipped with THRESHOLDS control connection, the comparison result may be used to control: - optical signalling devices (SIGNAL mode), - batching devices (IMPULS mode). In standard configuration the scale is set up to cooperate with optical signalling device. On the outputs P1 and P2 the short-circuit states appear, which depend on comparison results of balance indications with threshold values. THRESHOLDS outputs states chart (with increasing balance load) for both modes: SIGNAL mode: IMPULS mode:
In IMPULS mode on outputs P1 (threshold I) and P2 (threshold II) short-circuit impulses appear for about 0, 5s. [. . . ]