User manual CAME ZR22
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CAME ZR22. We hope that this CAME ZR22 user guide will be useful to you.
Manual abstract: user guide CAME ZR22
Detailed instructions for use are in the User's Guide.
[. . . ] SAFETY PRECAUTIONS
• Do not install the appliance if it is connected to the power supply. The Installation and service/repair must be performed by a qualified technician, in compliance with the producer's instructions and following local safety norms. Do not repair or replace any parts of the appliance unless it is specifically written in the user instructions. Make sure that the power supply cord is long enough to allow the right connection. [. . . ] Swing button
FAN
adjustment procedure Indoor fan speed alternates among High, Medium and Low each time this button is pressed. Press it once, the vertical adjustment louver swings to change vertical airflow direction. For horizontal airflow direction please refer to the chapter "Airflow direction control". 13
501932602028:Layout 1
1-12-2008
17:02
Pagina 14
Clock function You can adjust the real time by pressing CLOCK button, then using and buttons to get the correct time, press CLOCK button again: the real time is set. sLEEP mode SLEEP mode can be set in COOLING or HEATING operation mode. In SLEEP mode, • The appliance will stop operation automatically after operating for 8 hours. Set temperature will rise by max 1°C if the appliance operates in cooling mode for 2 hours. Set temperature will decrease by 3°C at most if the appliance operates in heating mode for 3 hours. *Note: In cooling mode, if room temperature is 26°C or above, set temperature will not change. oN
JET mode • JET mode is used to start or stop fast cooling. Fast cooling operates at high fan speed, changing the set temperature automatically to 18°C. Note that operation will be abnormal, in this case unplug from the power supply and re-plug after 2-3 seconds. This smell may come from another source such as furniture, cigarette etc, which is sucked in the unit and blown out with the air. Normal behaviour caused by the flow of refrigerant in the air conditioner. The sound may be generated by the expansion or contraction of the front panel due to temperature changes. Normal behaviour due to cool air discharged from indoor unit during COOLING or DRY operation mode. Does not run
No cooling or heating air
Ineffective control
Does not operate immediately Peculiar smell A sound of running water Cracking sound
Mist sprays from the outlet
17
501932602028:Layout 1
1-12-2008
17:03
Pagina 18
INSTALLATION INSTRUCTIONS
Installation diagram
Distance from wall should be over 50mm Distance from ceiling should be over 50mm
Distance from the wall should be over 50mm
Distance from floor should be over 2000mm
Air intake distance from the wall should be over 250mm
Air intake distance from the wall should be over 250mm
Ai shor out uld let be dist ov anc er e f 50 rom 0m m the wa ll
Over 250mm
NOTE: The figure above is only a simple presentation of the unit, it may not match the external appearance of the product you purchased. Installation must be performed in accordance with the national wiring standards by authorized service people only. 18
501932602028:Layout 1
1-12-2008
17:03
Pagina 19
Select the best location Location for Installing Indoor Unit • Where there is no obstacle near the air outlet and air can be easily blown to every corner. Observe the required distance from ceiling and wall according to the wiring diagram. Keep the unit and remote control 1m or more from television, radio etc. To prevent the effects of a fluorescent lamp, keep the unit as far as possible from it. [. . . ] Power supply from Indoor unit, including 7K, 9K, 12K, 18K Model
HEAT PUMP Indoor unit Terminal
Brown Blue
COOLING ONLY Outdoor unit Terminal
Brown Blue
Indoor unit Terminal
Outdoor unit Terminal
Brown Brown
1L
N
1L
N
Power connecting cord 1
Brown Brown Blue Blue
Blue
Power connecting cord
Blue
Power connecting cord
Yellow/Green Yellow/Green
Yellow/Green
Yellow/Green
23
501932602028:Layout 1
1-12-2008
17:04
Pagina 24
• Power supply from outdoor unit, including 24K Model For these models, the power supply is connected from outdoor unit, with a circuit breaker. HEAT PUMP Indoor unit Terminal Outdoor unit Terminal
Gray
COOLING ONLY Indoor unit Terminal
Oran ge(G ray)
Outdoor unit Terminal
Oran ge(G ray)
Brow n Blu e(B lac k)
3L 2L 1L
Gray
3L 2L 1L L
Black
Brown Brown
Black Power connecting cord 1
Brow n Brow n Blu e
Brown k) lac e(B Blu
re e n ow /G
Power connecting cord
ll Ye
/G ow e re
Ye ll
n
L N
e Blu
Ye llo w/ Gr ee n
Power connecting cord
Ye llo w /G re en
Terminal
N
Terminal
L N
Power supply
Power supply
• Defrost Cable (for heat-pump air conditioner only, and it's an optional part)
Defrost wire (indoor)
Defrost wire (outdoor)
Defrost cable (for heat pump models only) After connection, the defrost wire should be well wrapped with a wrapping tape and the connector should be put inside the unit. 24
501932602028:Layout 1
1-12-2008
17:04
Pagina 25
OUTDOOR UNIT INSTALLATION
1. Install Drain Port and Drain Hose (for heatpump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. [. . . ]