If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI PINGUINO PAC GSR. We hope that this DELONGHI PINGUINO PAC GSR user guide will be useful to you.
Manual abstract: user guide DELONGHI PINGUINO PAC GSR
Detailed instructions for use are in the User's Guide.
[. . . ] - Before moving the air-conditioner, empty water from collection tray. - To disconnect, turn any controll to "OFF" then remove plug from wall outlet. - Important: If you need to use an extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge).
SAVE THESE INSTRUCTIONS
2
Dear user, We thank you for purchasing the Pinguino air-conditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. [. . . ] In this case, use the special support belts (supplied with the appliance).
Attention
Connection and disconnection of the refrigerant couplings should be carried out by qualified personnel.
INTERNAL UNIT
The internal unit should be installed in the room to be conditioned. Generally, the ideal position for the internal unit is under a window. The air intake and outlet grilles should not be obstructed in any way.
The external unit can be installed above or at the same level as the internal unit, provided that the difference in height between the two units does not exceed 1. 5 m. CONDENSATION DRAINAGE The condensation which forms when the unit is used for air-conditioning (i. e. If the humidity is particularly high, it may be necessary to fit the condensation discharge tube (supplied with the machine). In this case, fit the hose to the coupling on the bottom section of the external unit (remove the rubber cap from the coupling). When specific applications require it, the condensation drainage can be done directly from the discharge pipe on the back of the unit. Should this happen, water will be collected into a tank and automatically removed through a pump system. Such a pump has to be installed separately and is available at any air conditioning contractors in your area.
EXTERNAL UNIT
The external unit can be positioned on a terrace or balcony. The external unit can also be mounted on a wall.
334 mm
Rubber cap Ring
Coupling
249 mm
8
ELECTRICAL CONNECTIONS
Before plugging the unit into the power supply, check the following: · the power supply voltage must be the same as the voltage shown on the rating plate · the power socket and the voltage circuit must be suitable for the power requirements of the unit · the socket must be suitable for the plug; if not, have the socket replaced.
· · ·
Do not place objects of any kind on the airconditioner. Make sure that there are no sources of heat in the room.
FINAL CHECK
In order to ensure that your air-conditioner operates with the maximum efficiency, make sure that: · all doors and windows in the room to be airconditioned are closed (except for temporary installation, in which case a window must be left partially open).
Close the door
Close the windows · Draw the curtains and/or partially close the blinds to protect the room against direct sunlight. This will increase the efficiency and economy of the air-conditioner.
Lower the blinds
Do not cover Draw the curtains YOUR AIR-CONDITIONER IS NOW READY FOR USE
9
CONTROL PANEL
TIMER ON signal lamp "Alarm" warning light "Fan" signal lamp "Air-conditioning" signal lamp
1 2
O I
OFF
4 5
6
MIN
Min. airconditioning signal lamp
3
ON
7
MAX
A
B
C
D
Timer notches
Thermostat knob ON/OFF main switch key Timer key
Fan speed selection key Fan/conditioning selection key
SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. If for example it is 4:00 p. m. , turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 (4 p. m. ) is lined up with the arrow pointer (the arrows indicates 4:00 p. m. 2) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 mins. ). 3) Check that the timer indicates the correct time (see instructions on setting).
Funzionamento Operating time
11
10
9
eg. from 9 to 11 a. m.
4
11
10
9
4
arrow pointer
N. B. : Never turn the dial in an anti-clockwise direction!The timer is in effect, an electric clock and works only if the plug is connected to the power supply. Whenever the plug is disconnected or there is a power failure, the programmer stops (the clock is then "slow") and must be re-set. The unit can be used in either programmed or
4) Select the desired function as shown in the chart overleaf. N. B: To override the programmed operating times, simply press the ON/OFF timer key. NON-PROGRAMMED MODE 1) B TIMER button must be pressed 2) Select the desired function as shown in the chart on the following page.
10
HOW TO START UP THE CONDITIONER
Plug the appliance into the wall socket. [. . . ] This warranty shall not apply to any AIRCONDITIONER which shall have been repaired or altered outside our factory nor shall it apply to any AIR-CONDITIONER which has been subjected to misuse, negligence or accidents. If repairs become necessary or spare parts are needed, please write to: SERVICE PH. Park 80 West Plaza One, 4th floor
GARANTIE
Nous garantissons que tous les appareils électriques DE'LONGHI sont exempts de tout défaut de matériaux et de manufacture. Notre obligation sous cette garantie est limitée au replacement ou à la réparation, gratuit en notre usine, de toutes les pièces défectueuses autres que les pièces endommagées durant le transport, qui nous seront retournées transport payé d'avance - endèans un an après la livraison à l'acheteur-utilisateur. [. . . ]