User manual ELECTROLUX LAUNDRY SYSTEMS T4250 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELECTROLUX LAUNDRY SYSTEMS T4250. We hope that this ELECTROLUX LAUNDRY SYSTEMS T4250 user guide will be useful to you.


ELECTROLUX LAUNDRY SYSTEMS T4250 INSTALLATION: Download the complete user guide (336 Ko)

You may also download the following manuals related to this product:

   ELECTROLUX LAUNDRY SYSTEMS T4250 DATASHEET (204 ko)
   ELECTROLUX LAUNDRY SYSTEMS T4250 DATASHEET (211 ko)
   ELECTROLUX LAUNDRY SYSTEMS T4250 DATASHEET (204 ko)
   ELECTROLUX LAUNDRY SYSTEMS T4250 DATASHEET (204 ko)
   ELECTROLUX LAUNDRY SYSTEMS T4250 DATASHEET (202 ko)

Manual abstract: user guide ELECTROLUX LAUNDRY SYSTEMS T4250INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] counter-pressure: Heat effect 9 kW Heat effect13. 5 kW Steam heating 650 Pa 520 Pa 520 Pa 270 Pa Gas piping: Gas pressure: See page regarding pressure Sound pressure level: < 70 dB (A) ISO 7/1-R1/2 < 70 dB (A) < 70 dB (A) 487 14 22 21 - 4250/4350 GB 8 Installation manual Technical data - type 4350 Heating Drum volume: Weight net: Drum: Diameter Depth Revolutions per minute Electric 349 litres 169 kg 760 mm 770 mm 45 rpm 17, 5 kg Electric heating: Gas heating: Steam heating: 13. 5 kW/18 kW Gas 349 litres 169 kg 760 mm 770 mm 45 rpm 17, 5 kg Steam 349 litres 184kg 760 mm 77 mm 45 rpm 17, 5 kg Capacity: Heat effect: 21 kW Depending upon steam pressure Air consumption: Heat effect 13. 5 kW Heat effect 18 kW Heat effect 21 kW Steam heating Piping evacuation: Piping steam: Steam in Steam out 600 m3/h 1000 m3/h 1000 m3/h 1000 m3/h Ø 200 Ø 200 Ø 200 ISO 7/1-R1 ISO 7/1-R1 Max. counter-pressure: Heat effect 13. 5 kW Heat effect 18 kW Heat effect 21 kW Steam heating 520 Pa 270 Pa 270 Pa 270 Pa Gas piping: Gas pressure: See page regarding pressure. Sound pressure level: < 70 dB (A) ISO 7/1-R1/2 < 70 dB (A) < 70 dB (A) 487 14 22 21 - 4250/4350 GB Installation manual Technical data - motor specifications Dryer with reversal: Blower motor 3-phase: Effect Revolutions per minute: 50 Hz 60 Hz 0. 75 kW 2700 rpm 3200 rpm 9 Drum motor 3-phase: Effect Revolutions per minute: 50 Hz 60 Hz 0. 25 kW 2700 rpm 3200 rpm Dryer without reversal: Drum / blower motor 1-phase: Effect Revolutions per minute: 50 Hz 60 Hz 1. 0 kW 2700 rpm 3200 rpm Drum / blower motor 3-phase: Effect Revolutions per minute: 50 Hz 60 Hz 0. 75 kW 2700 rpm 3200 rpm 487 14 22 21 - 4250/4350 GB 10 Installation manual Setup Unpacking When unpacking the machine, handle it with care. The drum has no transport clamps. 1 Fastened to the pallet The dryer is fastened to the pallet by 2 screws. [. . . ] 3 To avoid a draught in the room, it is advisable to place the air inlet behind the dryer. The area* of the air inlet opening must be 5 times the size of the vent pipe area. The resistance in the grating/slats on the air inlet cover plate should not exceed 10 Pa (0. 1 mbar). *The area of the inlet opening is the area through which the air can flow without resistance from grating/slatted cover. Note that gratings/slatted covers often block half of the total fresh air vent area. Remember to take this into account. 2 A 5xA XXXX X 24 05. 01 487 19 3 5xA 487 14 22 21 - 4250/4350 GB Installation manual Evacuation system for installation of several machines with a shared evacuation pipe Evacuation pipe Fig. 1 It is recommended that each dryer be connected separately to a smooth air outlet pipe with the lowest possible friction. For safety reasons it is important that the dryer is connected to a smooth evacuation pipe with a 200 mm diameter. When installing several machines on shared evacuation pipe, increase the area of the pipe with each additional machine so that each dryer will be working at the same air resistance. Fig 1 and the below table show in simplified form how the evacuation pipe should look. 1 15 2 The outlet The pipe must end outside in the open. In cold areas, condensation may cause frost damage to the building. Installation in frigid laundries In frigid laundries and where the air resistance is very low it can be a problem to reach 12°C within the given time (Error code E18 will be displayed). In this case it will be necessary to throttle the outlet air on the damper in the evacuation pipe. Gentle bends Fig. To keep the air flowing, ensure proper dryer operation, and minimize lint build-up in the exhaust system, never connect ducts at right angles, always use gentle bends. The evacuation pipe diameter must not be reduced. 5 400 6 450 7 475 8 500 9 535 10 560 No. By opening / closing the damper B the static pressure at A is either lowered or raised. 1 120 Table with static pressure The optimum air volume is achieved if the pressure is adjusted according to the table below. Type Effect kW Static pressure Pa A 30 B 4250 4250 4350 4350 4350 4250/4350 9 13, 5 13, 5 18 21 ** 760* 660 660 435 435 435 ** = Steam heated * It can be difficult to obtain a static pressure of 760 Pa if the vent pipes are very short. The static pressures in this table are not to be mistaken for the counter-pressure from the pressure drop curve. 487 14 22 21 - 4250/4350 GB Installation manual Steam installation Before start The steam pipe must be cut off and must not be under pressure. 19 Steam Steam 3-10 bar absolute pressure (130180°C). 5 a b Steam forward 1. The branch pipe's branch must be located at the top of the main steam pipe to prevent condensation in the steam. The branch pipe must have a descending gradient and must end at a height above the inlet connecting branch (5). Mount a plug valve (a) and a dirt collector (b) in the branch pipe. O 6 a bc N M Condensation return 1. It is important that the branch pipe for condensed water on return to the main condensate pipe has a descending gradient and is lower than the outlet connecting branch (6). Mount pressure hoses between branch pipes and dryer (hoses are not supplied). 487 14 22 21 - 4250/4350 GB 20 Installation manual 1 Steam-heated dryer Mounting steam calorifier on dryer Dryer type 4250: The steam calorifier is on the pallet. Demount supporting rail on the dryer, see arrow (note which way the supporting rail turns as it has to be remounted the same way, see step 5). [. . . ] 1. 25A connection this connection (1. 25A) can be used as connection of an external fan. Connect earth conductor to earth terminal in terminal for external connection. 100mA N 230V K7-2 K7-4 K7-6 K7-14 K7 External connection Max. 1. 25A 487 19 69 48. 01 487 14 22 21 - 4250/4350 GB 28 Installation manual To be carried out by qualified personnel Function check Check whether the drum is empty and the door has been closed. 1 Start the machine Check whether the door lock is working: The drum must stop if the front door is opened. Correct direction of rotation Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTROLUX LAUNDRY SYSTEMS T4250




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTROLUX LAUNDRY SYSTEMS T4250 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.