User manual EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER. We hope that this EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER user guide will be useful to you.


EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER : Download the complete user guide (723 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual pH 1100/ pH 2100 Bench pH/Ion Meter Technology Made Easy . . . 68X090818 Rev. 3 07/03 Instruction Manual pH 1100/ 2100 PREFACE Thank you for selecting the pH 1100/ 2100 benchtop meter. This meter measure pH, millivolts, relative millivolts and temperature. The instruction manual serves to explain the use of the pH 1100/ 2100 bench meter as a step-by-step operational guide to help you familiarize with the meter's features and functions. [. . . ] 4. 5. Mode 31 Instruction Manual pH 1100/ 2100 10. 2. 5 pH Measurement Alarm Setup Program P1. 3 Use this program to select alarm for low and high pH measurements. Enter pH/Temperature setup mode as described in steps 1-4 in 10. 2. 1 Entering pH/temperature setup mode (page 30). · · If you selected On continue to step 6 If you select Off, pressing ENTER returns to the setup mode. pH Meas. 4. Off pH Alarm On Select & Press ENTER Figure 88 5. Key In Low Alarm pH Set Point:2 . 000 Figure 89 Press /MI key to continue to the next setup program, or press /MR to go to the previous program. If you selected On, the display now reads Key in Low Alarm pH Set Point. If you make a mistake, use the /MI or /MR keys to highlight mistake, then re-enter. The high alarm must be set at least 1. 0 pH greater than the low alarm. If you make a mistake, use the /MI or /MR keys to highlight mistake, then re-enter. Press ENTER to confirm high pH set point value and return to the setup mode. Press /MI key to continue to the next setup program, or press /MR to go to the previous program. Press EXIT to return to the pH measurement mode. Key In High Alarm pH Set Point:14 . 000 Figure 90 7. 8. 32 Instruction Manual pH 1100/ 2100 10. 2. 6 pH Calibration Due Alarm Setup program P1. 4 Use this program to set a reminder when the next calibration is due. Enter pH/Temperature setup mode as described in steps 1-4 in 10. 2. 1 Entering pH/temperature setup mode (page 30). · · If you selected On, continue to step 6 If you select Off, pressing ENTER returns to the setup mode. pHCalDue Alarm : P1. 4 Press ENT. to Select Figure 91 2. Cal Alarm Due: On Off Select & Press ENTER Figure 92 3. 4. Keyin Cal Due Period (1-365 days) = 1 Figure 93 5. Press /MI to continue to the next setup program, or press /MR to go to the previous program. If you selected On in step 5, the display reads Key in Cal Due Period (1-365 days) =. If you make a mistake, use the /MI or /MR keys to highlight mistake, then re-enter. Press ENTER to confirm number of days to next calibration, screen flashes Sys Updating, Please wait. . . Press /MI key to continue to the next setup program, or press /MR to go to the previous program. Press EXIT to return to the pH measurement mode. 33 Instruction Manual pH 1100/ 2100 10. 2. 7 Stability Setup Program P1. 5 Use this program to turn on or off the pH stability indicator and to set level of stability (low, medium or high). [. . . ] Temperature changes also affect the signal the pH electrode sends to the meter and causes a loss of accuracy for the reading. To limit the loss of accuracy during calibration, make the temperature of the pH buffer calibrating solutions and the sample solution the same. 13. 2 pH Buffer Calibration Solution You can use standard buffer solutions to calibrate a pH meter before you measure the pH of a sample. Calibration solutions serve as basis of comparison between measurements. For 1-point calibration, use a standard buffer of pH 7. 00 or 6. 86, or a standard or custom buffer whose pH value is close to that of the sample. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS CYBERSCAN PH 1100 2100 PHION METER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.