[. . . ] · Do not use the V·Check mode to measure voltages in circuits that could be damaged by this mode's low input impedance (2 k). · Turn off power to the circuit under test before cutting, desoldering, or breaking the circuit. · Do not apply more than 600V rms between a meter terminal and earth ground. [. . . ] Do not use V·Check to measure voltage in circuits that could be damaged by a 2 k load. Hint: V·Check can be effectively used to eliminate "ghost" voltages. 16 MULTIMETER If AC detected If DC detected Meter puts 2 k load on circuit. Disable and re-enable V·Check For , and , Disables V·Check and locks meter in selected mode. 2 sec OFF A CAT V·Check 600V TEMPERATURE COM + or Re-enables V·Check or or ip09i. eps Temperature 16 MULTIMETER F C OFF A CAT V·Check 600V TEMPERATURE COM + 80BK Integrated Temperature Probe (Type K) Vent or Pipe ip19f. eps Note correct connector polarity. To meet stated accuracy, the 80BK temperature adapter must be at the same temperature as the meter. W Warning To avoid possible electric shock, DO NOT apply thermocouple tip to any conductor that is greater than 30V AC, 42. 4V pk, or 60V DC to earth. Capacitance E Turn off circuit power; then disconnect and discharge the capacitor before measuring capacitance. 16 MULTIMETER If the capacitor requires more discharging, diSC is displayed while the capacitor discharges. OFF A CAT V·Check 600V TEMPERATURE COM + 1 µF 10 µF 100 µF 10, 000 µF + ip05i. eps Note correct probe polarity for polarized capacitors. Microamps µA Range 0 to 200 µA 16 MULTIMETER µA AC µA DC OFF A CAT V·Check 600V TEMPERATURE COM + Flame sensor probe Control module ip20i. eps Example: Flame rectification circuit. Turn heating unit on and record µA measurement. Diode Test G Turn off circuit power before testing. Also refer to V·Check. Good Diode 16 MULTIMETER Typical voltage for silicon diode 16 MULTIMETER Low Impedance V·Check OFF A CAT V·Check OFF A CAT V·Check 600V TEMPERATURE 600V TEMPERATURE COM + COM + Single beep ip03i. eps Forward Bias Bad Diode 16 MULTIMETER Reverse Bias 16 MULTIMETER OFF A CAT V·Check OFF A CAT V·Check 600V TEMPERATURE 600V TEMPERATURE COM + COM + or ip04i. eps Shorted Open MIN MAX µF (Records the lowest and highest measurements) V·Check, autoranging, and Battery Saver are disabled. When the reading changes more than about 50 digits, the meter gives a short beep. When a new minimum or maximum is recorded, the meter gives a long beep. Enter Present Reading with MIN MAX Input Change Alert TM Maximum Reading 2 sec To Exit Minimum Reading ip10i. eps MIN MAX with Elapsed Time µF Records the hours and minutes between when MIN MAX was entered and the last high and low was recorded. To enable the MIN MAX timer, hold down M while turning the rotary switch from OFF to either measurement mode. Enter MIN MAX. View Present Reading Maximum Reading Maximum Reading Elapsed Time 2 sec Minimum Reading Elapsed Time Minimum Reading Exit MIN MAX ip11i. eps To disable the beeper for all modes, hold down r for 2 seconds while turning the meter on. Disabling the Beeper Continuity Capture To set up the meter to capture intermittent shorts and opens, turn the switch to GR, connect the leads to the circuit; then press M. ip12i. eps Captures transitions longer than 250 µs (1/4000th of a second). Transitions after the first transition cause the meter to beep, but the display does not change. To exit, press M for 2 seconds, or change the measurement mode. Maintenance Clean the case with a damp cloth and detergent. Battery Replacement Remove the test leads before disassembling the case. Replacement Parts Fluke TL-75 (Double-insulated leads) PN 855705 80BK (Integrated Temperature Probe) PN 1273124 Service and Parts This meter should be serviced only by a qualified service technician. To locate an authorized service center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www. fluke. com. C O M 60 0V + + ip13i. eps Specifications Accuracy is specified for a period of one year after calibration, at 18°C to 28°C (64°F to 82°F) with relative humidity to 90%. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows: ±([% of reading] + [number of least significant digits]) Function Temperature Range -10°C to 400°C 14°F to 752°F Resolution 0. 1°C or 0. 2°F 0. 1°C or 0. 2°F Accuracy ±(1. 0% + 0. 8°C) typical ±(1. 0% + 1. 5°F) typical ±(5. 0% + 1. 5°C) typical ±(5. 0% + 3. 3°F) typical Accuracy (Type K Thermocouple) -40°C to -10°C -40°F to 14°F Error does not include Type K Thermocouple errors. Function Range 4000 mV 4. 000V 40. 00V 400. 0V 600V 1 4000 mV 4. 000V 40. 00V 400. 0V 600V 400. 0 4. 000 k 40. 00 k 400. 0 k 4. 000 M 40. 00 M 1. 000 µF 10. 00 µF 100. 0 µF 10000 µF 1 Resolution 1 mV 0. 001V 00. 01V 000. 1V 1V 1 mV 0. 001V 00. 01V 000. 1V 1V 0. 1 0. 001 k 0. 01 k 0. 1 k 0. 001 M 0. 01 M 0. 001 µF 0. 01 µF 0. 1 µF 1 µF ±(1. 9% + 3) ±(1. 9% + 3) f ±(1. 9% + 3) (50 to 400 Hz) ±(1. 9% + 3) ±(1. 9% + 3) ±(0. 9% + 2) ±(0. 9% + 2) ±(0. 9% + 1) E ±(0. 9% + 1) ±(0. 9% + 1) ±(0. 9% + 2) ±(0. 9% + 1) ±(0. 9% + 1) ±(0. 9% + 1) ±(0. 9% + 1) ±(1. 5% + 3) ±(1. 9% + 2) ±(1. 9% + 2) ±(1. 9% + 2) | 1000 µF ±(1. 9% + 2) >1000 µF ±(10% + 90) typical ML 2. 000V 0. 001V ±(1. 9% + 2)2 1. [. . . ] This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE 2063513




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE 2063513 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.