User manual FLUKE FPG8601

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE FPG8601. We hope that this FLUKE FPG8601 user guide will be useful to you.


FLUKE FPG8601 : Download the complete user guide (3031 Ko)

Manual abstract: user guide FLUKE FPG8601

Detailed instructions for use are in the User's Guide.

[. . . ] FPG8601TM/VLPCTM Operation and Maintenance Manual © 2007 DH Instruments, a Fluke Company FPG8601TM/VLPCTM OPERATION AND MAINTENANCE MANUAL High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. © 2007 DH Instruments, a Fluke Company All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of DH Instruments, a Fluke Company 4765 East Beautiful Lane Phoenix Arizona 85044-5318 USA. [. . . ] Changes made to any parameter logged in the header is not reflected in the completed data file. For best use of the data file, do not make changes to the program configuration after the run mode begins. Most changes will not be reflected in the data file. 6. 5. 4 [RUN TEST SEQUENCE] [Run Test Sequence] is available only after one of the other run modes have been selected. Use this option to execute a test sequence created with the <Test Sequence Editor> (see Section 6. 6. 5). FPG Tools automatically sets each test pressure and averages the results according to the test sequence. When all test cycles are complete, FPG Tools automatically sets [Run Monitor] mode and vents all system pressure. For this reason, test sequences are a good way to safely run long, multi cycle tests overnight. The steps involved with running a test sequence are described below. © 2007 DH Instruments, a Fluke Company Page 66 6. FPG Tools provides a default data file name that can be edited as desired (see Section 9. 2. 1). If a pressure cycle is specified in the test sequence, the VLPC is set to a range that best accommodates the pressures in the pressure cycle. The maximum then minimum pressure cycle pressures are set for the number of pressure cycles specified. This pressure cycle occurs only one time, at the beginning of the first test cycle. A VLPC range is selected that allows the maximum test sequence pressure up to the first range change in the test sequence or the end of the test, whichever comes first. The hold and stability limits specified on the <Control> tab of the test sequence are set at this point. The test sequence begins stepping through the test points starting with the first test point in the test sequence. If the test point specifies a range change, FPG Tools detects the best range to use for the test points between the current point and the end of the test, whichever comes first. This optimum range is automatically set if it is not the active range. The default hold limits are used whenever the VLPC pressure range is changed in the middle of the test sequence. If the test point specifies a tare, the system is automatically tared in the same fashion as the [Zero System] toolbar function (see Section 5. 2). An internal calibration will be executed for every point that is zeroed when <Auto run internal calibration while zeroing> is enabled (see Section 5. 2). The test pressure is automatically set using the VLPC when it is active. Otherwise, a prompt is provided for the operator to manually set the test pressure. [. . . ] Products which have been changed or altered in any manner from their original design, or which are improperly or defectively installed, serviced or used are not covered by this warranty. DHI and any of its Authorized Service Providers' obligations with respect to this warranty are limited to the repair or replacement of defective products after their inspection and verification of such defects. All products to be considered for repair or replacement are to be returned to DHI, or its Authorized Service Provider, freight prepaid, after receiving authorization from DHI or its Authorized Service Provider. The buyer assumes all liability vis-à-vis third parties in respect of its acts or omissions involving use of the products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE FPG8601




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE FPG8601 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.