User manual FLUKE MOLBOX ANALOG CIRCUIT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE MOLBOX ANALOG CIRCUIT. We hope that this FLUKE MOLBOX ANALOG CIRCUIT user guide will be useful to you.


FLUKE MOLBOX ANALOG CIRCUIT : Download the complete user guide (332 Ko)

Manual abstract: user guide FLUKE MOLBOX ANALOG CIRCUIT

Detailed instructions for use are in the User's Guide.

[. . . ] DH Instruments, DH, DHI, molbox, molbox1 are trademarks, registered and otherwise, of DH Instruments, Inc. 5500093b-04 020604 Printed in the USA. © 1997-2002 DH Instruments, Inc. TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I FIGURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Either change the baud rate with the number keys and select [ENTER], or bypass it to view the next parameter by pressing enter. Repeat Step for Parity, Word Length and Stop Bits, and terminating characters. Select the proper configuration on the Serial Communications Form and press [OK]. Page 1 © 1997-2002 DH Instruments, Inc. MFC SWITCHBOX USER'S MANUAL NOT E S © 1997-2002 DH Instruments, Inc. Page 2 2. RUNNING A CALIBRATION 2. 2. 1 RUNNING A CALIBRATION OVERVIEW Before running a calibration, connect the 25 pin connector end of the calibration cable to the MFC port and the other end to the voltage or current measuring channel of the multimeter. The red plug is positive voltage, the black plug is negative voltage, the blue plug is positive current and the white plug negative current. When performing a Voltage mode calibration only connect the Red and Black connectors to the multimeter. Current (mA) calibrations should only have the blue and white connectors attached. Leaving different mode connectors attached or letting any connectors come in contact during a calibration could damage the molbox circuit. 2. 2 CHECK CALIBRATION The first step is to check to see if the calibration is out of specification. This is accomplished by selecting a Voltage or Current mode Calibration Check from the Test menu (see Section 3. 5). The software will set two points, 5 and 0. 5 V or 20 and 5 mA, without correcting with the molbox sense line. After each setting a prompt on the status bar to enter the current multimeter reading displays. The area of input will highlight and you must type in the multimeter reading and press return. The multimeter will only display the proper value when you are prompted; so wait for the prompt before entering the reading. It is important to make sure that the value is properly input into the text box as this will directly affect the results of the calibration. The agreement between the multimeter readings and those read back from the molbox must be less than ± 0. 1 % full scale for set values and ± 0. 05 % full scale for the measure values for molbox1. If this is the case, the molbox1 is in tolerance and there are no other necessary steps. However, if the molbox is out of tolerance then a recalibration is necessary. Page 3 © 1997-2002 DH Instruments, Inc. MFC SWITCHBOX USER'S MANUAL 2. 3 RECALIBRATE A recalibration determines new calibration coefficients for the set, measure and sense lines based on the supplied multimeter readings. To perform a recalibration, choose either a Voltage or Current mode Recalibration from the Test Menu (see Section 3. 6). The software will set 5 and 0. 5 V or 20 and 5 mA depending on the type of calibration selected. After each set point the multimeter readings must be entered when prompted in the same manner as a calibration check, except it will do it twice. The first time the software will calculate new adders and multipliers and write them to molbox1. The second time, the software is attempting to verify that the new calibration was successful. Therefore, the second set of data input by the user should be within the molbox specification. Once the calibration passes, the save calibration option displays (see Section 3. 1). If for some reason the calibration fails, the original calibration values are restored. Its purpose is to view previous calibration files and configuration (. cfg) files. 3. 5 TEST: CHECK MOLBOX CALIBRATION A Calibration Check should be performed anytime the circuit is in question. As a result, it is disabled when calibrating one of these units. 3. 6 TEST: RECALIBRATE MOLBOX This option should be selected to update the calibration coefficients of molbox1. [. . . ] All products to be considered for repair or replacement are to be returned to DHI, or its authorized service provider, freight prepaid, after receiving authorization from DHI or its authorized service provider. The buyer assumes all liability vis-à-vis third parties in respect of its acts or omissions involving use of the products. In no event shall DHI be liable to purchaser for any unforeseeable or indirect damage, it being expressly stated that, for the purpose of this warranty, such indirect damage includes, but is not limited to, loss of production, profits, revenue, or goodwill, even if DHI has been advised of the possibility thereof, and regardless of whether such products are used individually or as components in other products. Items returned to DHI under warranty claim but determined to not have a defect covered under warranty or to not have a defect at all are subject to an evaluation and shipping charge as well as applicable repair and/or calibration costs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE MOLBOX ANALOG CIRCUIT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE MOLBOX ANALOG CIRCUIT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.