[. . . ] SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSM09HV03/R2(DB) HSM09HV03/R2(DB) 2HUM18H03/R2(DB) HSM09HV03/R2(DB) HSM12HV03/R2(DB) 2HUM18H03/R2(DB)
Please read this operation manual before using the air conditioner
No. 0010557179
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled . Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. [. . . ] For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select DRY operation On the displaying board, colorful displaying bar will be light blue
3. Select temp. setting
FRESH
POWER/SOFT
Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly. Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting.
5. Unit stop
Press ON/OFF button, the unit stops.
11
Operation
Fan Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select FAN operation On the displaying board, colorful displaying bar will be pink.
3. Fan speed selection
FRESH
Press FAN button. For each press, fan speed changes as follows: Remote controller:
POWER/SOFT
LOW
MED
HI
4. Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP and POWER/SOFT operation is not available.
12
Operation
Heat Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select HEAT operation On the displaying board, colorful displaying bar will be red
3. Select temp. setting
FRESH
POWER/SOFT
Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
13
Operation
Air Flow Direction Adjustment
1. Status display of air sending
Vertical flap
Pos. 1 Pos. 1 Pos. 2 Pos. 3
FRESH
Horizontal louvers
Pos. 2 Pos. 3 Pos. 4 Pos. 5
Pos. 4
POWER/SOFT
Pos. 5 Pos. 6
(Auto swing)
Pos. 6 Pos. 7 Pos. 8
2. Up and down air flow direction
For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 6 remote controller: : HEAT: remote controller: AUTO: remote controller:
Pos. 5 Pos. 4 Pos. 3 Pos. 2 Pos. 1 Pos. 6
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pos. 5
Pos. 6
The vertical flap will swing according to the above positions
3. Left and right air flow direction
For each press of remote controller:
Pos. 1 Pos. 2 Pos. 3
button, remote controller displays as follows :
Pos. 4 Pos. 5 Pos. 6 Pos. 7 Pos. 8
The horizontal louvers will swing according to the above positions. Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. 14
Operation
Sleep Operation
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. setting so that room temperature won't be too Iow for your sleep.
SLEEP operation starts SLEEP operation stops Approx. 6hrs Rises 1OC 1 hr
1 hr
Rises 1OC
Temp. setting
Unit stop
In COOL, DRY mode
Remote Controller
2. In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting so that room temperature won't be too high for your sleep.
Temp. setting 1 hr Decreases 2OC 1 hr Decreases 2OC 3 hrs 3 hrs SLEEP operation starts
Rises 1OC
Unit stop
SLEEP operation stops
In HEAT mode
FRESH
POWER/SOFT
3. In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode. 5. Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. [. . . ] Use this switch in the test operation when the room O temperature is below 16 C, do not use it in the normal operation. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi". After 30 minutes, test operation ends automatically.
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode. [. . . ]