User manual LIFT-MASTER CROWN JEWEL SOFTWARE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER CROWN JEWEL SOFTWARE. We hope that this LIFT-MASTER CROWN JEWEL SOFTWARE user guide will be useful to you.


LIFT-MASTER CROWN JEWEL SOFTWARE : Download the complete user guide (1276 Ko)

Manual abstract: user guide LIFT-MASTER CROWN JEWEL SOFTWARE

Detailed instructions for use are in the User's Guide.

[. . . ] 2. 00 AND UP Crown Jewel (with Camera) Crown Jewel (Brass Enclosure) User's Guide TABLE OF CONTENTS Getting Started System Requirements . · System Requirements · Installing CJWin · Starting CJWin · The Main Menu · CJWin "Help" Features · Set Up a New Unit (Overview) Page 3 Page 3 Page 4 Page 4 Page 5 Page 5 System Requirements To run CJWin software, your system must have an IBM PC-compatible computer running Windows 95 (full version) or higher, Internet Explorer 4. 01 (Service Pack 2) or higher (5. 0 or higher recommended) and the following: MINIMUM Pentium 166 Processor 32 MB of RAM 200 MB hard disk free Hayes-compatible modem connected to a COM port CD ROM Mouse RECOMMENDED Pentium II Processor 128 MB of RAM 300 MB hard disk free Installing CJWin In order for CJWIN to operate properly, it must be installed onto the computer hard disk drive. CJWIN cannot be executed directly from the CD. · Windows 95 Users: You must have Y2K Update installed on your machine. · Windows 98 (before Second Edition) Users: You must have Y2K Update 2 installed on your machine - does not apply to Windows 98, Second Edition. [. . . ] Example: You could choose NUM for the prefix, then select "2#" from the drop-down menu of choices. To send direct commands, you would press "2#"; to enter programming mode (the Password Prefix) you would press "22*" (see Figure 8). 18 E D I T U N I T C O N F I G U R AT I O N Edit Unit Configuration Alarm Condition Breach or Strikeout Alarm Phone Number 5554433 Rings Before Answer 5 Pulse Dial 9 Enable Visitor Response Keys 9 Alternate Prefixes Allow Direct Commands from Installation No 5 20 Override Interval Yes 2 1 * Num 1# 1# 2# 3# 4# 5# 6# 7# 8# Done # None Normal Mixed * Command Prefix = 1# Password Prefix = 11* None House 10 Remote Both Activation Times 10 Auxillary Relay is Control Status Input 2 is Telco Connected Exit Request No Yes 200 of 1 Position Sense Thresholds: Off-Hook 20 Unit number 1 On-Hook FID 322410 Sets the direct command (##) and programming (***) prefixes Figure 8: Alternate Prefixes (NUM) ALLOW DIRECT COMMANDS FROM To enter direct commands from a remote telephone, enable the Allow Direct Command From option. Example: If you forgot to latch the gate attached to Relay 1, you can call the Crown Jewel unit and give it the direct command to latch the relay. For exact instructions, see the Crown Jewel Advanced Features Programming manual. · To enable the Allow Direct Commands From feature, select "Yes". · To disable the Allow Direct Commands From feature, select "No". ACTIVATION TIMES Activation Time sets the period of time (in seconds) when the relays will remain activated. RELAY 1 RELAY 2 Activation Times 10 10 The relay activation time can be set anywhere from 1 to 250 seconds. Factory Setting: 10 seconds. IMPORTANT NOTE: If one (or both) of the relays activate a gate operator with a momentary closure, set the relay activation time for a short period of time (for example, 2 seconds). If you set the relay activation time for a longer period of time, there is a possibility that the gate will continue to open and close until the relay activation period has ended. 19 E D I T U N I T C O N F I G U R AT I O N AUXILIARY RELAY AND STATUS INPUT 2 The area titled "Auxiliary Relay Is" allows you to select the mode of operation for the unit's second relay and status input. The selections include: · Relay 2=Control, Status 2=Exit Request 2: Relay 2 will activate when you dial a "5" on your telephone during a visitor call or when the Exit Request Device has been activated. · Relay 2=Shunt, Status 2=Position Sense 1: Relay 2 will activate whenever the main relay activates to temporarily bypass an alarm sensor monitoring this entry. · Relay 2=Alarm, Status 2=Position Sense 1: Relay 2 will activate if (1) the controlled entry is forced open, (2) if the entry is held open for more than one minute after the main relay has deactivated, or (3) the Maximum Keypad Errors feature has been violated. · Relay 2=CCTV Manual, Status 2=Position Sense 1: Relay 2 will activate the closed circuit TV when you dial a "5" on your telephone during a visitor call. · Relay 2=CCTV Instant, Status 2=Position Sense 1: Relay 2 will activate the closed circuit TV when the main relay activates. · Relay 2=Control, Status 2=Position Sense 1: Relay 2 will activate when you dial a "5" on your telephone during a visitor call or when the Position Sense device has been activated. Telephone Company (Telco) Connected The Telco Connected area tells the Crown Jewel if there is a telephone company line connected to it. The Crown Jewel will need this information because if it thinks that there is a telephone company line attached and it does not detect a dial tone, normal operation may be interrupted. · If the unit is connected to a telephone company line, select "Yes". · If the unit is not connected to a telephone company line, select "No". Unit and FID Number · Unit Number: Sequential number that the installer assigned to the unit that has the telephone line attached to it. This number can be between 1 and 7 but, in most installations, it will be "1". · FID Number: (6) six-digit factory set number located on the processor chip label (Main Processor Board). Your installer should have given you these numbers when the unit was installed. 20 T I M E Z O N E S A N D H O L I D AY S This section will cover . [. . . ] Retrieve the transactions from the unit if you haven't done so already (refer to page 32 for details). The Transaction Report Setup screen will appear (see Figure 20). Transaction Report Setup Range of Records to Print Starting Record Ending Record Up 10 Record First 1 Last 213 Up 1 Down 1 Time Stamp Down 10 Details Up 10 Up 1 Down 1 Down 10 4/3/02 1:21:00 PM 5/20/02 10:57:00 AM Modem, Step 14 Call Forwarding number 166122. . . House, Password, Valid Categories Optional Columns Margins (Inches) Entry Code Visitor Program Step Other All Record Number Category Top 0. 000 Left 0. 000 Font Print Done Click to select first record to print Figure 20: Transaction Report Setup Screen 35 PRINTING Printing Transactions (continued) CONFIGURING THE REPORT OPTIONS Range of Records to Print: The range of transactions that are currently located in CJWin's memory are displayed in the two boxes at the bottom of the Range of Records to Print area. To begin the printed list of transactions with a transaction other than 1, click UP 1 or UP 10 until the desired transaction is located in the starting transaction box. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER CROWN JEWEL SOFTWARE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER CROWN JEWEL SOFTWARE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.