User manual LIFT-MASTER ROBO SWING

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER ROBO SWING. We hope that this LIFT-MASTER ROBO SWING user guide will be useful to you.


LIFT-MASTER ROBO SWING : Download the complete user guide (7533 Ko)

Manual abstract: user guide LIFT-MASTER ROBO SWING

Detailed instructions for use are in the User's Guide.

[. . . ] copyright © 2004 chamberlain professional products - www. eliteaccess. com TABLE OF CONTENTS 2 2 3 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35-36 37 38 39 40-41 41 42 43 Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Swing Gate Systems Warnings and Precautions Safely Operating Gate Configuration and Specifications Concrete Pad and Gate Attachment Standard Installation Compact Installation Gate Arm Installation Gate Movement Direction Adjustment of Output Shaft Earth Ground Rod DC Power Supply Connection "Optional" Solar Panel Surge Suppressor Terminal Input Connections Adjusting Gate Traveling Distance Timer Adjustment Reversing Sensor Warning Placard Placement Emergency Release Safety Device Wiring "Optional" Input Board Maglock Wiring Connection Optional 12 VDC Photo Beam Wiring 3-Push Button Wiring Connection 3-Push Button Wiring Master / Slave Single Operator Loop Size and Placement Master / Slave Loop Size and Placement Loop Installation and Number of Wire Turns Wiring Loop Detector to Operator Master and Slave Operators with Timer Master and Slave Operators without Timer Control Board Functions Control Board LED Descriptions Troubleshooting How to Reset Breaker Switch / How to Check Fuses Gate will not close!If you hear a "BEEP" sound (Audio Alarm) Robo Swing Parts Illustrations, Robo Swing Parts List Maintenance Elite Robo Swing Accessories Owners Checklist of Installation Please DO NOT Touch me!. . Unless you are an Authorized Service Technician! © COPYRIGHT 1992-2003 BY ELITE ACCESS SYSTEMS, INC. No part of this manual may be reproduced in any means; graphic, electronic, mechanical, or photocopied without the express written permission of the publisher of this material. Release 7 7/03 For Toll Free Technical Support: 1-888-ELITE-10 35483 1 ROLE OF SPECIFIERS AND DESIGNERS Specifiers and designers should design an automatic vehicular gate system to: · · · · · · · · · Utilize an operator suited for gate system type, size, frequency of use, location and user population. [. . . ] For further details about Elite's solar panel, consult the "Solar 3" Installation sheet that is included with the solar panel. ® ® CAUTION Do Not use solar panel and plug-in transformer at the same time. AC ­ AC ACCESS SYSTEMS INC R Solar Panel (Elite Part # SOLAR 3) No Stand POWER INPUT 18 VAC ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ + RADIO RECEIVER Polarity Does Not Matter POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON CLASS 2 SUPPLY Energizing this operator with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery . CAUTION Elite recommends using a larger battery (12 VDC, 30 AHr) (Elite Part # A 12330) in this operator when using the optional solar panel. 12 VDC 0 AHr 3 For More Details, contact your Local Dealer 17 SURGE SUPPRESSOR TERMINAL CONNECTIONS The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23). ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + RADIO RECEIVER CLASS 2 SUPPLY 4 Wire -12 VDC Radio Receiver To 115 VAC Polarity does NOT Matter 13 12 11 11 + Red Radio (+12 VDC) Grey Radio (Relay) ­ Black Radio (-) ­ Grey Radio (Relay) AC AC Plug-In Transformer 18 VAC 1 4 External "Safety" Loop Detector 12 VDC 10 9 Card Reader 10 9 Push Button 1 4 Photo Beam (Safety) 12 VDC 10 9 Phone Entry 1 4 7 HELP 2 5 8 0 3 6 9 5 6 External "Exit" Loop Detector 12 VDC 8 7 Fire or Any Key Switch 18 ADJUSTING GATE TRAVELING DISTANCE Release the red handle and open the gate to a distance desired. Turn limit cam until the half moon shape hits the limit switch and you hear the switch click. For a more precise adjustment, use the set allen screw. Limit Cams Adjust Limit Cams Limit Switches Allen Screw Loosen Screw ADJUSTABLE TIMER If you want to use the automatic close for the gate system the timer switch should be put in the "ON" position. If you want to use the push open or push close command, the timer should be switched to the "OFF" position. CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON TIMER Set Timer 0 to 60 seconds UP PW STOP OVERLOAD POWER J2 ALARM SENSOR REVERSE SENSOR ON 60 OFF HEAVY GATE 0 CLOSE CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONT FIRE DEPT ROL OPEN STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC ON 60 OFF 0 TIMER ON UP PW STOP OPEN TO RIGH T 60 0 CLOSE OFF 19 W1 CLOSE STOP TIMER UP PW ADJUSTABLE REVERSING SENSOR Adjust the "Reverse Sensor" pot on the upper portion of the control board. The level of reverse sensitivity depends on the weight of the gate and the condition of installation. Not sensitive enough = if the gate hits an object and does not stop or reverse. Do Not Touch Alarm Sensor Pot Minimum Sensitivity HEAVY GATE CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 Important Note! There is a "Heavy Gate" LED which will light up when the gate is heavier than normal. This is a diagnostic LED and the operator will still function normally when this indicator is on. SYSTEM ON ALARM SENSOR ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW REVERSE SENSOR OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO FIRE DEPT STRIKE OPEN L STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIGHT Maximum Sensitivity WARNING PLACARD PLACEMENT Warning placards need to be permanently mounted on BOTH sides of the gate. 20 W1 OPEN EMERGENCY 1 Unscrew Bolt Special tool required for the "optional" security bolt RELEASE 2 Lift Off Cover 3 Loosen Red Handle Gate can now be manually moved Grab the Gate to Make Adjustments Tighten the Red Handle, Replace the Cover and Bolt when Finished When the power is turned on again, the gate will readjust itself automatically. 21 SAFETY DEVICE WIRING Sensing Edges ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + RADIO RECEIVER CLASS 2 SUPPLY Sensor Edges Top of Gate Sensor Edge Wires 1 4 Important: gate will stop and reopen upon activation of device Photo Beam Entrapment Protection Optional input board needed to preform this function P/N Q412 PATENT PENDING Elite Part # A OMRON12V 7 8 9 10 11 12 13 16-Pin Plug 1 3 5 7 9 11 13 15 16 ­ FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + RADIO RECEIVER 2 4 6 8 10 12 14 3&4 Black Orange CHECK CHARGINGFUSE BOARD POWER POWER ­+ Blue Brown SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD HEAVY GATE 11 13 POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO L FIRE DEPT STRIKE OPEN STOP TIMER UP PW SAFETY LOOP EXIT LOOP RADIO REC If photo beam is blocked the gate will stop. The gate will remain stopped until the beam is cleared. W1 OFF Cut W1 Jumper at Bottom of Board Wall OPEN TO RIGHT Danger Gate Open Mounted Reflector 22 W1 CLOSE Important: ON 60 0 OPEN "OPTIONAL" INPUT BOARD The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. 1&2 3&4 5&6 7&8 9 &10 d 11 & 4 12 & 7 13 & 14 15 & 16 Open Switch (N. O. ) Stop Switch (N. C. ) (Cut W1 Jumper at Bottom of Board) Timer Close Output to Slave Timer Input from Master (Close Command or Close Switch) (N. O. ) Alarm Output will be set off with very heavy gates or object preventing gate operation. (Not Burglar Alarm) (9 = +12 VDC, 10 = Alarm) Emergency Open Switch (Direct Command from Battery to Motor) Emergency Close Switch (Direct Command from Battery to Motor) Magnetic Lock - Dry Contact Relay (13 = Com, 14 = N. C. ) Center Loop Option (For Swing Gate Operators Only) W1 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOAR D POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL FIRE DEPT 23 OPEN MAGLOCK WIRING CONNECTION The "Optional" input board MUST be used to perform this function. (Elite Part# Q203) Custom Bracket Magnetic Lock Plate Magnetic Lock Gate Fence Elite Part # A MG 1300 Relay Contact Rating 0. 5 Amp - 125 VAC 1 Amp - 24 VDC Dry Contact Relay 14 13 N. C. Common Power for Maglock 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOAR D POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL OPEN 24 FIRE DEPT OPTIONAL 12 VDC PHOTO BEAM SAFETY WIRING ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ ­ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + + RADIO RECEIVER CLASS 2 SUPPLY Orange 1 (Elite Part # A OMRON 12V) (Failsafe) 4 White Blue 11 Brown 13 Power Photo Beam (Safety) 12 VDC It is best to use 12 VDC Failsafe Photo Beam Sensors for this Safety Option Failsafe Photo Beam: If a failsafe photo beam is not working or loses power or photo beam is blocked, then the photo beam will stop all gate operation. Important: If photo beam is blocked the gate will stop and reopen. The gate will remain open until the obstruction is cleared. Contact your local dealer for more information. 25 3­PUSH BUTTON WIRING CONNECTION The "Optional" input board MUST be used to perform this function. (Elite Part# Q203) There can be NO common wires within this 3-push button station. Open-N. O. Contact 2 4 8 N. C. 1 3 7 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 ALARM SENSOR Cut W1 jumper at the bottom of Board to use the stop button in the 3-push button station REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA W1 CENTRAL CON TROL FIRE DEPT STRIKE OPEN STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIG HT 26 W1 OPEN 3­PUSH BUTTON WIRING MASTER/SLAVE The "Optional" input board MUST be used on both operators to perform this function (Elite Part# Q203). A 12 VDC Double Pull Double Throw (DPDT) 3 Amp Minimum Relay must be used (Not Included). There can be NO common wires within this 3-button station. 1 3 ® ® 2 4 D 12PDT ReVDC 3 Am lay p Mini Com Com NO NO AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­+ ­ + POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON RADIO RECEIVER CLASS 2 SUPPLY Open-N. O. [. . . ] Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the "OFF" position. RADIO REC For further information, contact your local dealer. 38 AUDIO ALARM If you hear a ALARM SENSOR "BEEP" sound. . . . . . . The gate is TOO heavy. The operator arm or gate is incorrectly installed. ALARM SENSOR Horizontal Gate Level line Vertical Gate Level line Incorrect Incorrect ALARM SENSOR A foreign object is on the gate frame while the gate is moving. ALARM SENSOR The gate is moving and a car pushes the gate. ALARM SENSOR Gate hinges are too tight or broken and the gate is not moving freely. ALARM SENSOR The gate hits the driveway, curb or other, and gets stuck or bent in an awkward position. 39 ROBO Q084 Q118 SWING Q063 PARTS CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 Q206 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE Q268 Q062 Q214 BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTROL FIRE DEPT STRIKE OPEN STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIGHT Q060 Q412 P/N PENDING PATENT RESS E SUPP O SURG ROB INC SYSTEMS OR Q061 Q058 Q059 ACCESS ® ® S2 CLAS LY SUPP RADIO ER RECEIV SAFETY LOOP INPUT POWER 18 VAC EXIT LOOP OPEN N STRIKE BUTTO DEPT PUSH FIRE SWITCH KEY Q205 Robo SW/SL Conversion Kit Limit Switch Assembly Q412 Q244 Q057 Q049 Q029* Q050 Q055 Q238* Q140 Q165 Q203 Q212 Q183 Q162 Q181 1. 5A - 250V 1. 5A - 250V J2 Q206 Q123 Q022 Q412 P/N PENDING PATENT OR RESS E SUPP O SURG ROB INC SYSTEMS Q142 ACCESS ® ® S2 CLAS LY SUPP RADIO ER RECEIV SAFETY LOOP INPUT POWER 18 VAC EXIT LOOP OPEN N STRIKE BUTTO DEPT PUSH FIRE SWITCH KEY Q006 Q009 Q412 Arm Package Q214 A BT 12 Q104 Note: * Sold Individually, 2 Shown. For part list, refer to next page. 40 W1 OPEN PARTS PARTS Robo SW / SL Conversion Kit Robo SW Q206Conversion Kit / SL - Control Board Q214 - Limit/Motor Harness Q205 Q206 - Control Board Q205 Q214 - Surge Suppressor Terminal Q412 - Limit/Motor Harness Q412 - Surge Suppressor Terminal Limit Switch Assembly Limit Switch Assembly Q238 - Gate Adjustment (Plastic Part) Q165 Q238 - Gate Adjustment (Plastic Part) Q165 Q055 - Limit Switch Bracket Q055 - Limit Switch Bracket Arm Package Q104 Arm Package Q104 Cludge Assembly Cludge Assembly Q060 - Arm Release Handle Q061 Q060 - Arm Release Handle Q061 Q061 - Output Shaft Cludge (T) Q061 - Output Shaft Cludge (T) LIST LIST A BT 12 - 12 VDC, 7 amp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER ROBO SWING




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER ROBO SWING will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.