User manual NOVAK PIT WIZARD
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NOVAK PIT WIZARD. We hope that this NOVAK PIT WIZARD user guide will be useful to you.
You may also download the following manuals related to this product:
NOVAK PIT WIZARD (76 ko)
Manual abstract: user guide NOVAK PIT WIZARD
Detailed instructions for use are in the User's Guide.
[. . . ] PIT WIZARD instruction manual
CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 What's Included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-22 Saving Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] You would do this by decreasing the value for Full Throttle (Figure 11).
4. Use the {UP} or {DOWN} buttons to change the parameter value: 21 Neutral 1498µS (CONT. ) 18 PIT WIZARD INSTRUCTION MANUAL
EDITING PARAMETERS
(CONT. )
5. The display will change back to the Neutral sub-screen: 21 Neutral OPTIMUM SETTINGS: For optimum performance, your Cyclone settings should be 1350µS for Neutral, 1850µS for Full Throttle, and 1000µS for Full Brake. This will display as 500µS for full Throttle and 350µS for Full Brake in the Edit Profile mode. Press the {UP} or {DOWN} buttons to display the next desired adjustable parameter. To display and modify Full Throttle (sub-screen 22), Full Brake (23), Deadband (24), Minimum Drive (26), and Drag Brake Value (29), repeat Steps 3 through 5 .
Note: Deadband, Minimum Drive, and Drag Brake Value are entered as a percentage to the nearest percent (1%) up to 50%. To display and modify Drive PWM Frequency (25), Brake PWM Frequency (27), or Drag Brake Frequency (28), use Steps 3 through 5. There are 16 frequency values to choose from: Select Freq 23. 4KHz
% FULL BRAKE % FULL DRIVE
100 100
DEADBAND
50
50
20 10
20
TRIGGER
Full Brake Neutral
POSITION
Full Throttle
10
Figure 11: Graphical display of the Full Throttle position shifted toward Neutral
for Drag Racing.
PIT WIZARD INSTRUCTION MANUAL
19
EDITING PARAMETERS
(CONT. )
9. The Toggle Options are two position switches that turn on and off features in the Cyclone speed control. One (1) indicates that the features is turned on, and a zero (0) is off. To modify the Toggle Options (2A): ·Press the {ENTER} button at the Toggle Options sub-screen: 2A Toggle Opt. ·Eight toggles that can be switched will be displayed: Toggle Select 00000000 ·Press the {UP} or {DOWN} buttons to move left or right and select which toggle to switch (The toggle with a line under it). ·Press the {ENTER} button to change the selected toggle.
Note: Currently, only the first toggle from the left controls a feature in the Cyclone. This toggle will allow the Drag Brake Value to be adjusted with the Brake pot on the speed control.
The second toggle from the left indicates whether or not the throttle channel on your tranmitter is reversed. If this toggle displays a "1" (rev. ), a "#" symbol will also be displayed to the left of the value on the Full Throttle and Full Brake sub-screens. For Drag Brake ON the display should read: Toggle Select 10000000 ·Press the {MODE} to make Toggle changes and exit back out to the Toggle Options sub-screen: 2A Toggle Opt. Press {MODE} button again to exit back out to the main menu.
20
PIT WIZARD INSTRUCTION MANUAL
DOWNLOADING PARAMETERS TO CYCLONE
This section outlines the steps that will allow you to download the parameters that are currently displayed in the Pit Wizard's Edit Profile mode into the Cyclone speed control's Profile 4. The downloaded Profile will always be the active Profile in the Cyclone even if this is the first time Profile 4 has been activated. You will now have the original three Profiles that came with the Cyclone, plus the user-programmable Profile (Profile 4) to choose from through the One-Touch button. Refer to your Cyclone Owner's Manual for instructions on selecting Profiles with the One-Touch button. IMPORTANT NOTE: You must upload Profile 1, 2, or 3 from your Cyclone to get the values for Neutral, Full Throttle, and Full Brake for any new Profile to be downloaded. These values can NOT be re-programmed through the Cyclone's One-Touch Set-Up. [. . . ] 28, 29, 30 ProfilesRetrieving Stored . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 ProfilesSample . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
R
Reading ParametersProfiles Stored in Pit Wizard . . . . . 24
S
Sample Profile Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE NOVAK PIT WIZARD
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NOVAK PIT WIZARD will begin.