[. . . ] Z250-E1-02
Smart Sensor ZG Series
2D Profile Measuring Sensors
User`s Manual
Introduction
Thank you for purchasing the ZG series. This manual provides information regarding functions, performance and operating methods that are required for using the ZG. When using the ZG, be sure to observe the following: · The ZG must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] The output format is the same as that of the MEASURE command.
FUNCTION SETTINGS
p. 136
PROFILE (A) PROFILE (B) The profile is output. When profile (A) is selected, the profile is output in PROFILE 0 (ASCII) format. When profile (B) is selected, the profile is output in PROFILE 1 (binary) format. Auto output of profiles is not possible in the case of AUTO sensitivity.
p. 146
ZG User's Manual
I/O Settings
99
System Settings
Setting the Sensor Installation Status
Regular Reflection/Diffuse Reflection
Set how the Sensor is installed. This setting is automatically specified according to the type of the connected Sensor. However, if the Sensor is installed at an angle and the default value and reflection angle are changed, change the settings according to the status of the Sensor installation.
FUN mode-[SYSTEM]-[SENSOR SET]-[SET]
Setting value
DIFFUSE (diffuse reflection) REGULAR (regular reflection)
Description
Select this item when the Sensor is installed for diffuse reflection measurement. Select this item when the Sensor is installed for regular reflection measurement.
Sensor Installation Correction
This function corrects error caused by shifting of the inclination between the Sensor and reference plane of the measurement target. The measurement target is actually measured and the correction value is registered.
The angle of inclination () is calculated from the width and the difference in height of two locations, and registered. The profile is corrected by this angle of inclination at all times.
Important
The registered slope correction is cleared when the following settings are changed: · CCD mode · Sensor installation
100
System Settings
ZG User's Manual
FUN mode-[SYSTEM]-[SENSOR SET]-[CORECT]-[INCLINATION]
SYS/INC.
1
Set the measurement target in place, and select [TEACH].
1TEACH
SYS/INC. TEACH PROFILE YES N O
2
3
FUNCTION SETTINGS
Move to [YES] and press the SET key.
aaa
SYS/INC.
3
Select [SET].
1TEACH 2SET
SYS/INC.
4
Specify the start and end lines for point 1. ESC Key: Cancels the setting.
POINT1 START [128]LINE SET
SYS/INC. Select which position (average, peak or bottom) within the specified region is to be taken as the measurement point.
1AVE 2PEAK 3BTM
ZG User's Manual
System Settings
101
SYS/INC.
6
Specify the start and end lines for point 2. ESC Key: Cancels the setting.
POINT2 START [128]LINE SET
SYS/INC. POINT2 SELECT
7
Select the measurement point.
1AVE 2PEAK 3BTM
SYS/INC.
8
SET
Press the SET key to apply the setting.
Setting correction ON/OFF
Set Sensor inclination correction ON/OFF.
FUN mode-[SYSTEM]-[SENSOR SET]-[CORECT]-[CORECT]
Setting value
OFF ON
Description
Sensor inclination correction is not performed. (default value) Sensor inclination correction is performed.
102
System Settings
ZG User's Manual
Setting the CCD Mode
Set the resolution of the Sensor's CCD. The profile can be set to high-resolution or the response time can be speeded up by changing the CCD mode. CCD Mode p. 156
Important
When the CCD mode is changed, the bank data is initialized. So, be sure to start with teaching again.
FUN mode-[SYSTEM]-[CCD MODE]
Setting value
NORMAL (standard mode) HI-RESO (high-resolution mode) HI-SPEED (high-speed mode)
Description
Standard measurement is performed. (default value) Measurement is performed at a resolution of about four times that of the standard mode. Measurement is performed with the number of pixels halved in the height direction. This mode is suited to measurement of shapes in fast line speed processes as the measurement cycle is fast. Note, however, that the possible measurement distance becomes roughly 1/2 of the rated distance.
ZG User's Manual
System Settings
103
3
FUNCTION SETTINGS
Setting the RS-232C Communication Specifications
Set the communication specifications for the Controller matched to the communication specifications of external devices.
FUN mode-[SYSTEM]-[RS-232C]
Setting value
LENGTH PARITY STOP (stop bit) BAUDRATE DELIMITER
Description
8BIT, 7BIT (default value: 8 BIT) NONE, ODD, EVEN (default value: NONE) 1BIT, 2BIT (default value: 1BIT) 9600, 19200, 38400, 57600, 115200 (default value:38400) CR, LF, CR+LF (default: CR)
Setting the Node No.
This node No. [. . . ] When connecting the Controller to a PC for the first time, the USB driver must be installed in advance.
2
Turn the Controller ON.
Important
Make sure that the Controller's power supply is connected securely. When the power is turned OFF during a firmware update, the Controller breaks down and can no longer start up normally.
3
Set the Controller's mode switch to FUN.
196
Updating the Firmware
ZG User's Manual
Installing Warp Engine ZS
4
Starting Up Warp Engine ZS
Install Warp Engine ZS on the PC.
Important
Start Warp Engine ZS only when the PC recognizes the Controller normally.
5
Select [Programs]-[OMRON][WarpEngineZS] from the Windows [Start] menu. The [WarpEngineZS] window is displayed.
5
APPENDICES 197
If startup of Warp Engine ZS fails, a message is displayed, followed by the dialog box shown on the left. Updating the Firmware
ZG User's Manual
Setting the firmware information