If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-13UKP-ES2. We hope that this TOSHIBA RAS-13UKP-ES2 user guide will be useful to you.
Manual abstract: user guide TOSHIBA RAS-13UKP-ES2SERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] SVM-03001
SERVICE MANUAL
AIR CONDITIONER
SPLIT WALL TYPE
RAS-13UKHP-ES2 / RAS-13UAH-ES2 RAS-13UKHP-AS2 / RAS-13UAH-AS2 RAS-10UKHP-ES2 / RAS-10UAH-ES2 RAS-10UKHP-AS2 / RAS-10UAH-AS2 RAS-13UKP-ES2 / RAS-13UA-ES2 RAS-13UKP-AS2 / RAS-13UA-AS2 RAS-10UKP-ES2 / RAS-10UA-ES2 RAS-10UKP-AS2 / RAS-10UA-AS2
Feb. , 2003
FILE NO. SPECIFICATIONS CONSTRUCTION VIEWS
2-1 Indoor Unit 2-2 Outdoor Unit
3.
WIRING DIAGRAM
3-1 RAS-13UKHP-ES2 / RAS-13UAH-ES2 RAS-13UKHP-AS2 / RAS-13UAH-AS2 3-2 RAS-10UKHP-ES2 / RAS-10UAH-ES2 RAS-10UKHP-AS2 / RAS-10UAH-AS2 3-3 RAS-13UKP-ES2 / RAS-13UA-ES2 RAS-13UKP-AS2 / RAS-13UA-AS2 3-4 RAS-10UKP-ES2 / RAS-10UA-ES2 RAS-10UKP-AS2 / RAS-10UA-AS2
4.
SPECIFICATION OF ELECTRICAL PARTS
4-1 Indoor Unit (RAS-13UKHP-ES2, RAS-13UKHP-AS2, RAS-10UKHP-ES2, RAS-10UKHP-AS2) 4-2 Outdoor Unit (RAS-13UAH-ES2, RAS-13UAH-AS2, RAS-13UA-ES2, RAS-13UA-AS2) 4-3 Outdoor Unit (RAS-10UAHP-ES2, RAS-10UAH-AS2) 4-4 Indoor Unit (RAS-13UKP-ES2, RAS-13UKP-AS2, RAS-10UKP-ES2, RAS-10UKP-AS2) 4-5 Outdoor Unit (RAS-10UA-ES2, RAS-10UA-AS2)
5.
REFRIGERATION CYCLE DIAGRAM
5-1 RAS-13UKHP-ES2 / RAS-13UAH-ES2 RAS-13UKHP-AS2 / RAS-13UAH-AS2 5-2 RAS-10UKHP-ES2 / RAS-10UAH-ES2 RAS-10UKHP-AS2 / RAS-10UAH-AS2 5-3 RAS-13UKP-ES2 / RAS-13UA-ES2 RAS-13UKP-AS2 / RAS-13UA-AS2 5-4 RAS-10UKP-ES2 / RAS-10UA-ES2 RAS-10UKP-AS2 / RAS-10UA-AS2
6.
CONTROL BLOCK DIAGRAM
6-1 RAS-13UKHP-ES2 / RAS-13UAH-ES2 RAS-13UKHP-AS2 / RAS-13UAH-AS2 RAS-10UKHP-ES2 / RAS-10UAH-ES2 RAS-10UKHP-AS2 / RAS-10UAH-AS2 6-2 RAS-13UKP-ES2 / RAS-13UA-ES2 RAS-13UKP-AS2 / RAS-13UA-AS2 RAS-10UKP-ES2 / RAS-10UA-ES2 RAS-10UKP-AS2 / RAS-10UA-AS2
1
FILE NO. OPERATION DESCRIPTION
7-1 7-2 7-3 7-4 7-5 7-6 7-7 Outline of Air Conditioner Control Description of Operation Circuit Hi POWER Mode High-Temperature Limit Control Low-Temperature Limit Control Auto Restart Function Filter Check Lamp Safety Cautions Installation Diagram of Indoor and Outdoor Units Installation Indoor Unit Outdoor Unit How to Set Remote Control Selector Switch Others Troubleshooting Procedure Basic Check Items Primary Judgement Self-Diagnosis by Remote Control (Check Code) Troubleshooting Flowcharts Troubleshooting for Remote Control (Including The Indoor P. C. Board)
8.
INSTALLATION PROCEDURE
8-1 8-2 8-3 8-4 8-5 8-6 8-7
9.
TROUBLESHOOTING CHART
9-1 9-2 9-3 9-4 9-5 9-6
10. [. . . ] 8-4-8
2 1 3
· Put the power supply cord through the notch.
Fig. 8-4-5
Earth line
Terminal block
Cord clamp Screw Screw Screw
Power supply cord Power cord connect cover
Fig. SVM-03001
<How to connect the connecting cable> Wiring of the connecting cable can be carried out without removing the front panel. Insert the connecting cable (according to the local cords) into the pipe hole on the wall. Take out the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm from the front. Insert the connecting cable fully into the terminal block and secure it tightly with screws. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor unit.
Connecting cable
For RAS-13/10UK
Cord clamp Terminal cover Screw
12
Terminal block
12
abo
ut 1
5 cm
Earth line
Screw
Screw
Connecting cable
Fig. 8-4-11
Earth line
60 mm 10 mm
CAUTION
· Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical cords and also any specific wiring instructions or limitations. For RAS-13/10UKH
Terminal cover Cord clamp Terminal block
10 mm 50 mm
Stripping length of the connecting cable
Fig. · Wire type : H07 RN-F or more <How to install the air inlet grille on the indoor unit> · When attaching the air inlet grille, the contrary of the removed operation is performed.
Screw Connecting cable
abo
4
4
12
3
12
3
ut 1
5 cm
Earth line
Screw
Screw
Connecting cable
Fig. 8-4-13
10 mm
10 mm 50 mm
Stripping length of the connecting cable
Fig. Piping and drain hose installation <Piping and drain hose forming> * Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) Rear right
4 mm
How to fix the drains cap 1) Insert hexagonal wrench (4 mm) in a center head.
Left Bottom right Right
Die-cutting Front panel slit
Bottom left
Changing drain hose
Rear left
Piping preparation
Fig. 8-4-16 2) Firmly insert drains cap.
No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Die-cutting Front panel slit For leftward connection, cut out slit on the left side of the front panel. Changing drain hose For leftward connection, bottom leftward connection and rear leftward connection's piping, it is necessary to change the drain hose and drain cap. How to remove the drains cap Clip drain cap by needle-nose plier, and pull out.
Fig. 8-4-17
CAUTION
Firmly insert the drain hose and drain cap; otherwise, water may leak. <In case of right or left piping> · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool.
Fig. 8-4-14 How to install the drain hose Firmly insert drain hose connecting part until hitting on a heat insulator.
Slit
Fig. 8-4-18 <In case of bottom right or bottom left piping>
Heat insulator
· After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool.
Drain hose
Fig. [. . . ] 4) Remove the 2 screws on the heat exchanger at the 2 fixed plates (upper and lower) from the back body, and then pull out the upper side of the heat exchanger slowly. Remarks
2 Pipe holder
3 2-Screws
4 2-Screws
5
Cross flow fan
1) Remove the front panel, electrical part, horizontal louver and the heat exchanger following procedure 4. 2) Remove the 2 screws on the band motor (L) and remove the 2 screws on the band motor (R) and then remove the cross flow fan. 3) Loosen the set screw of the cross flow fan then separate the fan and the fan motor. [. . . ]